How to Replace a Recessed Fire Sprinkler Escutcheon
October 25, 2023
Replacing recessed fire sprinkler escutcheons can be easy or complex. QRFS reviews how to install skirts or the whole escutcheon, both listed and split-ring models.
October 25, 2023
Replacing recessed fire sprinkler escutcheons can be easy or complex. QRFS reviews how to install skirts or the whole escutcheon, both listed and split-ring models.
October 11, 2023
Learn how to use Reliable fire sprinkler data sheets (“Bulletins”) to identify and purchase the correct sprinklers and accessories for your fire protection system.
September 27, 2023
Amazon still sells some unlisted, non-compliant fire sprinklers. Learn why these are risky and how to avoid questionable products.
September 13, 2023
Learn how to use Senju fire sprinkler data sheets to identify the correct sprinklers, escutcheons, cover plates, and other parts for your fire protection system.
August 17, 2023
Fire sprinkler “cut sheets” can seem confusing—at first. Here’s a guide to reading Victaulic sprinkler data sheets to find the right specs, sprinklers, and other parts.
August 2, 2023
Tyco has updated some of its LFII sprinklers along with the cover plates that fit some of them. Here’s what’s changed and what you need to buy.
July 19, 2023
Reading fire sprinkler data sheets doesn’t have to be a head-scratching experience. Here’s how to read a Tyco sprinkler data sheet.
July 5, 2023
Fire sprinkler data sheets seem confusing but they’re easy if you know what to look for. Here’s how to read Viking fire sprinkler data sheets.
June 21, 2023
Fire sprinkler K-factor is crucial for system performance and protection. Learn what it is, why it’s essential, and how to find the right sprinkler.
June 7, 2023
Avoiding fire sprinkler obstructions is essential—but when do smaller objects like smoke detectors block sprinklers? QRFS explains the rules.
May 25, 2023
Finding and buying the correct fire sprinkler heads, escutcheons, covers, and wrenches can take a little research. Learn how QRFS’s Quick Finder makes it simple!
April 26, 2023
Many fire sprinkler escutcheons provide some leeway. Learn about fire sprinkler escutcheon adjustment types and which one you need.
April 12, 2023
When and why do you have to replace missing fire sprinkler escutcheons? QRFS explains the rules and reasons, examining the potential impacts on spray patterns and activation.
March 29, 2023
Fire sprinkler trim rings help cover holes that are too big for escutcheons or covers. Learn about metal & Kydex options for oversized wall and ceiling sprinkler penetrations.
March 1, 2023
Cover plates for concealed fire sprinklers come in different shapes, sizes & more. Learn what the options mean so you can pick the right cover plate for the job.
February 15, 2023
Learn why installers use reducing couplings, concentric reducers, or eccentric reducers in fire protection grooved pipe systems.